Get a complete and extended check out on the anatomical framework by means of panoramic imaging coupled with velocity sign and forward/backward scan skill earning scanning easier, smoother and even more controllable.
1.2.2 Warning Labels Warning Labels Meaning Please thoroughly read this guide before use device. The next labels undoubtedly are a. Usually do not position the device on the sloped floor. Or else the out there if the system unit may well slide, causing private harm or maybe the device operates Together with the cellular malfunction.
Do not use any cables aside from the cables delivered With all the unit by Mindray. 3. Make use of the cable furnished with This technique to connect the printer. Other cables may end in electrical shock. Web page fifteen: Mechanical Basic safety
The user will not be permitted to open up the covers and panel on the system, neither Notice: unit disassemble is authorized. To make sure the system effectiveness and protection, only Mindray engineers or engineers licensed by Mindray can execute servicing.
Permits usage of multiple scanned angles to sort an individual image, leading to Increased distinction resolution and enhanced visualization
Minimize off cable ties connecting the key device to the Show by diagonal slicing pliers, and then pull out the corresponding cable plugs.
Learn greater diagnostic information and facts via extended perspective of the anatomical framework on all linear probes
Mindray’s new era of black & white ultrasound technique, DP-50 Specialist, is equipped with Sophisticated imaging systems allowing further penetration and speedier image acquisition with higher resolution.
This handbook could referring to information guarded by copyright or patents and would not convey any license beneath the patent legal rights or copyright of Mindray, or of Other folks. Page 9: Assertion
The chapter materials the method to validate major perform and general performance of item. This is often only utilized for reference, not preventive execution. Perform checking and tests of this element shall be carried out by Mindray service engineers along with the user alongside one another. Webpage sixty six: General Examination
Observe: Around the monitor, the brightness adjustment comes before distinction. After readjusting the watch’s contrast and brightness, adjust all preset and peripheral configurations.
Observe: Just before inserting the connector in the probe port, inspect the connector pin. Should the pin is bent, do not use the probe right up until it has been inspected / fixed / replaced. Setting up Peripherals For the styles on the supported peripherals, remember to seek advice from “2.
Following replacing the CPU module, important file must be created Once more according to the new MAC handle and composed into HDD on the equipment. Or else, the configuration function on the merchandise is going to be lost. Soon after removing the CPU module, Remove panhead screws with washers (12 M3X6) mounted on the key unit box, you might take from the board. Page 118 Determine 8-29 Disassemble the Control Panel Assembly (1) Hold the higher edge of control panel assembly, and open up the control panel. Figure eight-30 Disassemble the Control Panel Assembly (two) After removing one countersunk head self-tapping screw PT3X10 preset on the control panel and choose out the plug with the keyboard and the leading unit connecting cables, you may take out the user interface Dp50rb login assembly.
Overall performance Check 5.five.one Take a look at System Resolution Detection depth Geometric Position Precision Blackout place take a look at History the exam pictures five.5.two Exam Content The graphic made use of here is just for reference, keep on with the graphic influence in the real Take note: problem. Necessities: Show: established the contrast and brightness for the medical application benefit (or maybe the default standing) Operation environment: dark area, simulating the clinical software setting. Page 76 In issue that the transverse resolution tests targets are horizontally displayed, document the nominal distance of two targets which might be Plainly acknowledged. Repeat the Procedure previously mentioned for your transverse resolution tests targets at other depths. As proven in determine beneath. Axial resolution ... Page 77 When utilizing the convex probe, preserve the transverse resolution tests targets to NOTE: be shown close to the midline. When employing a linear probe with steer operate, don't turn on the steer functionality when execute the transverse resolution test. Zoom while in the location in which the targets Positioned if essential. The diameter with the concentrate on level at a particular depth is equal to your transverse resolution in the depth. Site seventy eight five.
A wise new condition, Improved mobility and convenient operation make DP-fifty well suited for all medical configurations.
Your Instrument for deeper biopsy: permitting changes into the scan line to get superior visibility with the needle, nerves and smaller vessels, guaranteeing the continuity of all facts.